DFP300I Digital Pressure Transmitter
Low-power IIC digital pressure transmitter with pressure and temperature data output for compact OEM integration.
- Range and output selection support
- OEM configuration available
- Datasheet and technical response
Technical Specifications
| Measurement range | 0-100 kPa...100 MPa; specify the calibrated range |
|---|---|
| Pressure type | Absolute, gauge or sealed gauge |
| Output interface | IIC bus; pressure and temperature data |
| Supply voltage | 1.8-3.6 VDC; default configuration 3.3 +/-0.1 VDC |
| Pressure accuracy | +/-0.5% FS |
| Temperature accuracy | +/-1 deg C |
| Operating current | <=0.3 mA; standby approximately 0.1 microampere |
| Operating temperature | -40 to +80 deg C |
| Compensation temperature | -20 to +80 deg C |
| Protection rating | IP65 |
Source: Selection guide V1.0. Confirm the exact ordered configuration.
Electrical Connection
| Red | Power + |
|---|---|
| Black | Power - |
| Yellow | SDA |
| Blue | SCL |
Overview
The DFP300I digital pressure transmitter uses an oil-filled pressure sensor core with metal diaphragm isolation and built-in temperature compensation. It outputs pressure and temperature data through the IIC interface for compact OEM and industrial control applications.
Typical Applications
- Pharmaceutical, food-processing, and packaging equipment
- Compact OEM pressure modules
- Digital pressure and temperature monitoring
- Low-power industrial measurement systems
- Gauge, absolute, and sealed gauge pressure selection
Key Features
- Measurement range from 0-100 kPa to 100 MPa
- 15%-85% digital output over IIC bus protocol
- 24-bit high-precision analog-to-digital conversion
- Real-time temperature-drift compensation
- Low operating and standby current
Advantages for B2B Projects
- Digital interface carries pressure and temperature data
- Compact structure for embedded equipment
- Built-in compensation supports reliable pressure measurement
- Suitable for technical selection and custom project discussion
FAQ
What interface does the DFP300I use?
It uses an IIC communication interface for pressure and temperature data output.
What supply voltage is listed in the selection guide?
The guide lists 1.8 V to 3.6 VDC input and a default 3.3 V selection option.
Does the guide include assembly notes?
Yes. It recommends a floating assembly structure and protecting the front isolation diaphragm.
Technical Data & Selection Guide
Measurement range: 0-100 kPa…100 MPa
Input voltage: 1.8 V-3.6 VDC
Pressure accuracy: +/-0.5%FS
Output: 15%-85% over IIC bus protocol
Protection: IP65

Selection Guidance
DFP300I uses an IIC digital interface, not a 4-20 mA loop. Confirm the controller interface and low-voltage supply before integration. The guide recommends floating assembly without compression sealing on the sensor end face. Protect the isolation diaphragm, and confirm the seal configuration for temperatures below -20 deg C or harsh media.
Quotation Checklist
- Measured medium and application
- Required pressure, level, or temperature range
- Output signal and supply voltage
- Process connection and electrical connection
- Accuracy, protection, and operating temperature requirements
- Quantity, destination country, and OEM customization needs
Before You Request a Quote
For a faster technical response, include the installation environment, controller or PLC interface, expected order quantity, destination country, and whether you need a standard model, private label, custom cable, or special process connection.
Need a Datasheet or RFQ?
Send your technical requirements and our team will help confirm the suitable model and configuration.